Evaluating the impact of solar greenhouse thermal performance on reducing carbon dioxide emissions in contemporary buildings based on the Pareto method





Abstract
Rapid population growth, urbanization, and an increasing dependence on fossil fuels have led the building sector to account for approximately 40% of global energy consumption and 30% of carbon dioxide emissions, highlighting the urgent need for passive solutions and solar systems. Solar greenhouses, as transparent and semi-active spaces, possess a unique capacity to enhance solar energy utilization, improve thermal comfort, and reduce reliance on mechanical systems. While previous studies have investigated individual parameters such as installation orientation, glazing materials, or ventilation, these analyses have predominantly remained single-objective. A significant research gap exists regarding the simultaneous evaluation of multiple key design parameters—including thermal performance, energy consumption, and CO2CO_2CO2 emissions—within an integrated multi-objective framework for cold and dry climates. This study aims to address this gap.
In this research, the impact of a solar greenhouse on three primary indicators—annual cooling load, total annual energy load, and carbon dioxide emissions—was comprehensively evaluated. A baseline building model with dimensions of 8 ×\times× 8 meters and a height of 2.7 meters was developed, designed to accommodate greenhouse attachments on the south, east, and west sides. Three independent variables were defined: greenhouse orientation (south, east, and west), overhang depth (ranging from 50 cm to 2 m), and glazing type (single and double-glazed), resulting in 24 distinct design scenarios. Thermal behavior was simulated using DesignBuilder software, powered by the EnergyPlus engine, utilizing climate data from Hamedan to account for radiation, temperature, and environmental conditions. The model’s validity was confirmed through comparison with existing literature, yielding an acceptable error range. Extracted data were normalized to facilitate the comparison of objectives with differing units, and a multi-objective analysis was performed. Finally, a 3D Pareto front was generated to identify optimal scenarios, and the “distance from the ideal point” method was employed to determine the most effective design options.
The results indicated that glazing type and overhang depth exerted the most significant influence on all three dependent variables. The use of double-glazed glass significantly reduced heat transfer, energy consumption, and CO2CO_2CO2 emissions. Furthermore, increasing the overhang depth to 2 meters improved winter heat storage and reduced the total energy load, although a potential increase in summer cooling loads was noted, suggesting a need for intelligent ventilation design. Regarding orientation, it was observed that southern greenhouses receive maximum solar radiation during winter but require enhanced thermal management in summer, whereas eastern and western orientations receive more diffuse radiation and exhibit lower cooling loads. Notably, the combination of double-glazing and increased depth significantly diminished the performance variance between the three orientations, allowing all scenarios to achieve near-optimal performance.
Through Pareto front analysis, several scenarios featuring greater depth and double-glazing were identified on the optimal front. Specifically, the scenarios ED200, WD200, and SD200, characterized by the shortest distance from the ideal point, were identified as the optimal design options. These scenarios represent a balanced integration of cooling load reduction, energy load minimization, and CO2CO_2CO2 emission mitigation.

Keywords: Solar greenhouse, multi-objective optimization, thermal performance, carbon dioxide, Pareto front.